Features:
- 400 Tests Automatic Biochemistry Analyzer
analyzer is fully automatic,discrete,random access biochemistry analyzer.It is eupipped with:60 sample position,90 reagent position,and 120 reaction cuvettes.It is 400 test per hour,
1.Sample unit:
- Sample Settings: 60 sample positions, including calibration, quality control and emergency,
- primary tubes and serum is available.
- Sample Volume: 2ul ~50ul (0.1ul stepping).
2.Reagent unit:
- Reagent Position: R1 45 & R2 45,total 90 refrigerated reagent position.
- Reagent Volume: R1:25~300ul, R2:10~150ul (1ul stepping), supporting reagent of different brand
- Temperature Control: continuous cooling system working within 24 hours.
Specification:
Overall Performance |
Type |
discrete, fully automatic |
||
Throughput |
400 T/H |
|||
Analysis Method |
End-point, Fixed-time,Rate |
|||
Programming Items |
programmable for any test items |
|||
Sample unit |
Sample Settings |
90 sample positions, including calibration, quality control and emergency. |
||
Sample Volume |
2ul ~50ul (0.1ul stepping) |
|||
Sample Probe |
Having liquid level induction function. |
|||
Probe cleaning |
Automatic washing both interior and exterior |
|||
Analysis Items |
analyzing maximally 45 items at the same time |
|||
Reagent unit |
Reagent Position |
R1:45 R2:45 total 90 refrigerated reagent position |
||
Reagent Volume |
R1:25~300ul, R2:10~150ul (1ul stepping), supporting reagent from different brand |
|||
Temperature Control |
continuous 2C~8Ccooling within 24 hours |
|||
Reagent Probe |
Having liquid level induction function |
|||
Probe cleaning |
Automatic washing both interior and exterior |
|||
Reaction unit |
Reaction Time |
10 minutes |
Temperature |
37C±0.1C |
Cuvettes |
120 reaction cuvettes (optical path length 6mm) |
|||
Mixer |
after injecting reagent and sample, blending immediately |
|||
Cleaning |
automatic water cleaning and drying system |
|||
System Adjustment |
System record the blank value and get more accurate result by deducting blank base value of each cuvette |
|||
Optical System |
Light Source |
12V/30W halogen-tungsten lamp, 2000 hours |
||
Receiver |
8 precision photo receivers |
|||
Wavelength Range |
340,405,450,510,546,578,630,700mm |
|||
Calibration and QC |
Calibration |
one-point,multi-point |
Linear Range |
0.000~2.500Abs |
Quality Control |
inserting quality control at random. |
|||
Software |
Emergency Function |
emergency sample can be arranged at any time |
||
Software |
Windows XP or 7, sample and easy to operate |
|||
Data Processing |
Having reaction curve detection and data display function in whole process. |
|||
Others |
Power Supply |
AC220V+22V/50Hz+1Hz |
||
Dimension |
1070mm×910mm×1230mm (W*D*H) |