Features
- It can automatically optimize testing order, reduce waiting time, and improve testing speed.
- Automatic stirring and mixing, makes the mixture of sample and reagent more even, reaction more perfect.
- Stand-alone freon-free environmental protectional refrigeration system, refrigerating for 24 hours without a break, guarantee the quality of the reagent.
- Flexible and open reagent scheme, one reagent is available to many items.
- Free set of calculation item of multi-item participation.
- Completed quality-control scheme, different thickness of high, medium, low, support L-J and X-B quality control.
- Dynamic real-time reaction curve monitors the disabled reagent timely, prompt too high thickness and make automatic dilution of sample.
- Insert emergency at any time, and start emergency testing at first time.
- In running, the graphic guide-view system of reagent and sample tray makes it easier to provide the user to look over and master testing information.
- Strong database storage technology, hundreds of storage of result, with no influence to running speed.
- Complete setup to reference range as different sex and age provides convenience to clinical reference.
Specification:
Wavelength |
8 filters, 340,380,405,492,510,546,578,630nm, or match as user’s demand. |
Temperature control |
25°C, 30°C, 37°C±0.1°C |
Analysis method |
end point, dynamic, fixed time, sample blank, reagent blank, absorbency, double wavelength, etc. |
Testing speed |
100 samples/hour |
Reagent capacity |
3 reagent tray, 17 reagents/tray, 51 samples for one time (including standard). |
Crossed contamination |
<1% |
Computer |
Pentium computer chip |
Monitor |
big-screen color monitor |
Printer |
Outside high resolution printer |
Keyboard |
Standard computer keyboard |
Exterior interface |
bidirectional RS-232. USB interface |
Light source |
Long life halogen lamp, 12V,20W |
Reading cell |
A continuous flow-cell:Internal volume 33 ul, usual reading volume 500 ul |
temperature control |
37º C± 0.1º |
Reagent capacity |
Three reagent disks, eachdisk can hold 17 different reagents, 51 reagents supported totally |
Sample & reaction plate |
Round rotatingplate, with 45 positions for sample orstandard cups. 37º C thermostatcontrolled. 4 replaceable multi-cell sectors (24cells each). 96 reaction cellstotally. |
Automatic Calibration |
Automatic; 1-45 (optional) orstandard protein-based calibration solution |
Range of absorbency |
0 3 Abs Linearity: <1% |
CV |
<1% |
Power supply |
220V, 50Hz (optional 115V,60Hz) |
Power |
140W |
Weight |
38Kg |