Microwave Reaction System adopts the international advanced double magnetronFrequency microwave heating system and realizes
the high power microwave balanced magneticField safety heating. Microwave Reaction System has been widely used in food,
textile, plastic, geological, metallurgical, coal, biological medicine, petroleum chemical industry, environmental monitoring,
sewage treatment, battery manufacturing, cosmetics, etc.
Characteristic:
Double magnetron variable frequency control system: It could adjust microwave output continuously.
It makes the microwave field more uniform and more accurate that could ensure the sample digestion is uniform.
The high accuracy pressure sensor could make the pressure control more precise.
7"LCD color touch-screen real time display the temperature and pressure curve.
Built-in method library (50 methods for MRS-45C) and the methods could be programmed.
Feature:
Multiple safety protection function
It has more than ten safety protection measures to ensure experiment safety, including temperature control system,
pressure control system, and explosion-proof security doors, thicken cavity with 8 layer TEFLON coating,
High-power exhaust system, program with suspend or start at any time. Ladder-style control temperature system,
the material is TFM for the vessel and aerospace composite material for the vessel cover,
The vessel cap with PFA and the pressure shrapnel use PEEK.
Optical fiber temperature control system
The instrument adopts the internationally advanced optical fiber temperature control system. It avoids producing the spark which other temperature control mode caused, effectively eliminates microwave interference temperature control system and other factors. It not only achieves precision control temperature but also it is the most safe microwave digestion temperature control mode at present.
The ARM chip with UCOS -II operation system
It is suitable for the experimental preparation equipment which runs stably and operates easily.
The advantages of MRS-45C type are:
1.The MRS-45C Type is double screen, one 7" LCD color touch-screen, another 5" LCD Video monitor, can observed the dynamic experiment directly.
Other two types can't.
2. Remote control system- MRS-45C only, based on Wi-Fi technology, peer to peer control. Other two types don't have the function.
3. Digestion method: 50 preinstalled methods, programing 100 methods, more than other two types.
4.10 Teflon coating, more safety.
Model |
MRS-45C |
MRS-45B |
MRS-45A |
Cavity |
48L Resonant Cavity |
48L Resonant Cavity |
48L Resonant Cavity |
Digestion method |
50 preinstalled methods, programing 100 methods |
20 preinstalled methods, programing 50 methods |
15 preinstalled methods, programing 30 methods |
temperature measurment range |
-40°C - 305°C |
0°C - 305 °C |
Ambient temperature - 305°C |
Temperature accuracy |
±1°C |
±1°C |
±1°C |
Pressure accuracy |
±0.01Mpa |
±0.01Mpa |
±0.01Mpa |
Temperature control method |
Optical Fiber |
Optical Fiber |
Optical Fiber |
Max.pressure |
80Mpa |
70Mpa |
60Mpa |
Vessel volume |
100mL |
100mL |
100mL |
Vessel quantity |
12 Vessels |
12 Vessels |
10 Vessels |
Cooling method |
forced air cooling |
forced air cooling |
forced air cooling |
TEFLON coating |
10 layer |
8 layer |
6 layer |
Interface |
USB, RS232 |
- |
- |
Display |
7" LCD screen + 5LCD |
7" LCD screen |
7" LCD screen |
Control model |
touch screen |
touch screen |
touch screen |
Power supply |
220VAC±10% 50Hz |
220VAC±10% 50Hz |
220VAC±10% 50Hz |
Power output |
1600W |
1600W |
1600W |
Dimensions |
520mmx593mmx660mm |
520mmx593mmx660mm |
520mmx593mmx660mm |
Weight |
67Kg |
67Kg |
67Kg |