AAS-5000A Series

Availability: In Stock
Product Code: 1113
Brand: Atomic Absorption

AAS-5000A

$0

Summary: Characteristics 
◆ Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional) 
◆ Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.

Characteristics 

◆ Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)

◆ Integrated floated optical platform design can obviously improve the optical system shock resistance and     can keep stable though use the optical signal for a long term. 

◆ Eight light stands can be changed automatically and preheat the eight element lights meantime as well as     optimize  the working condition of the hollow cathode lamp

◆ Position adjusting: the best height of the flame burner and can automatically set the front and rear positions

◆ Fully automated wavelength scanning and peak searching

◆ Complete safety chains protection equipment: the function of warning and automatic safety protection           towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout

◆ Deuterium lamp and self-absorption background regulation 

◆ Data processing: super strong database, possesses more than 500 data self-storage and cutoff storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can  be randomly called

◆ Measuring method: flame absorption method and emission method

◆ Result printing: parameter printing, data result printing and diagram printing

Complete automatic controlling system 

With the help of the software, the following can be easily achieved

◆ Selection of the element lamp

◆ Up-down-front-rear adjustment of the lifter

◆ Adjustment of the optical energy

◆ Selection of the slit

◆ Determination of wavelength scanning and peak searching

◆ Selection of the atomizer

◆ Setting of the background deduction method 

◆ Controlling of the gas flow

◆ Automatic flaming and flaming out 

◆ Setting of the graphite furnace testing method 

Advanced graphite furnace temperature controlling technology

◆ The bringing in of PID technology can effectively overcome the influence on the temperature rising process   caused by the voltage fluctuation and the resistance change to make more accurate controlling process. 

The combination of  the 3/time fast sampling technique can make more accurate and reliable testing data

◆ The fast heating capacity can improve the flexibility of the elements further 

◆ Use the ordinary power source of 220V without need of dynamic power of 380V

◆ The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different  samples

◆ Three grades adjustable gas flow can accustom to more application needs  

◆ Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error Safe, reliable and convenient flame system    

◆ Epc can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can            operate easily 

◆ Efficient Atomization system enables a higher sensitivity 

◆ The whole operation system has a high security as the fire safety system can alarm whenever the electricity   is cut off, Abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off  the gas, prohibit tempering. Thus it keeps the operation people and equipment from harm and damage. 

Multi-functional software workstation 

◆ A workstation that is supported WINDOWS XP/2000/NT

◆ The rich menu brings great convenience to the use of customer

◆ Convenient conversion between different menus makes the operation more easily

◆ Various analytical correction methods provide the users more choices 

◆ Basic default parameter settings enable even the beginners can do the normal operation

◆ Flexible storage, editing and printing methods give the user largest support 

◆ Instrument configuration:

Atomic Absorption Spectrophotometer   1pc

Air compressor without noise     1pc 

PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)

A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)

Wavelength range

190 – 900nm

Spectral bandwidth

Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm

Accuracy of the wavelength

±0.15nm

Receptivity of the wavelength

≤0.04nm

Base line stability

≤0.002A/30min (Cu)

Characteristic viscosity

0.02μg/ml/1% (Cu)

Checking limit

0.004μg/ml (Cu)

Preciseness

0.5%

Grating

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer

Effective glass atomizer

Lamp stand

Eight lamps

Size and weight

700mm×550mm×450mm  75Kg

Power source

Po220V±22V  AC

D2 background correction ability

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction    method

Flame system 

Acetylene air burner

100mm

Nitrous oxide acetylene flame head

50mm

Ignition dynamic baseline drift

≤0.006A/30min

Cu) Characteristic viscosity

≤0.025μg/ml/1%

Related standard deviation of the accuracy

≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)

Safety system

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

Graphite furnace

The highest temperature

3000℃

The largest temperature rising speed

≥2000℃/S

Characteristic quantity

Cd≤0.5×10-12g  Cu≤0.5×10-11g

Accuracy

Cu≤3%  Cd≤3%

Size and weight

550mm×450mm×300mm 65Kg

Safety system 

Over current protection

Low air pressure alarm / protection 

 Low cooling water flow alarm/protection

Power source and power

220V±22V AC 7000W

Ordering Information:

AAS-5000APCS

Atomic Absorption  AAS-500 Including air compressor and pc with software

AAS-5000AGFPCS

Atomic Absorption ​ AAS-500 Including air compressor, graphite furnace and pc with software

Related Products