Multiparameter Ion meter, 5 points calibration, automatic help message display. The meter is suitable for measuring the pH, millivolts and ion concentration of liquids. Accuracy: 0.002pH, 1% full scale (Ion mode).
ion meterMode:
• Multiparameter ion meter is equipped with a large backlit LCD display.
• 1 to 5 points calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatically calculates and displays electrode slope that helps you decide whether to replace pH electrode.
ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurements provide accurate ORP readings.
Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify the type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units for different measurement requirements.
Other Features:
• Automatic Temperature Compensation ensures accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration improves the measurement accuracy of meter.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows the setting 10 parameters, including the pH buffer standards, number
of calibration points, resolutions, stability conditions, hold function, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
Model |
ION-30B |
|
pH |
||
Range |
-2.000~20.000pH |
|
Accuracy |
±0.002pH |
|
Resolution |
0.1, 0.01, 0.001pH |
|
Calibration Points |
1 to 5 points |
|
Calibration Solutions |
USA, NIST, DIN Standards |
|
Temperature Compensation |
0~100°C, 32~212°F |
|
Compensation Mode |
Manual or Automatic |
|
mV |
||
Range |
-1999.9~1999.9mV |
|
Accuracy |
±0.2mV |
|
Resolution |
0.1, 1mV |
|
Calibration Points |
1 point (Only for Relative mV mode) |
|
Calibration Range |
±200mV |
|
Ion |
||
Range |
0.001~19999ppm, mg/L, mol/L |
|
Accuracy |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
|
Resolution |
0.001, 0.01, 0.1, 1 |
|
Calibration Points |
2 to 5 points |
|
Calibration Solutions |
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L |
|
Temperature |
||
Range |
0~105°C, 32~221°F |
|
Accuracy |
±0.5°C, ±0.9°F |
|
Resolution |
0.1°C |
|
Calibration Range |
Measured value ±10°C |
|
Temperature Units |
°C or °F |
|
Others |
||
Hold Function |
Manual or Automatic |
|
Stability Conditions |
Low or High |
|
Calibration Due |
0 to 31 days |
|
Power Off |
Manual or Automatic (10, 20, 30 minutes) |
|
Reset Function |
Yes |
|
Memory |
Stores up to 500 data sets |
|
Output |
USB Communication Interface |
|
Connector |
BNC |
|
Display |
LCD (130×110mm) |
|
Power Requirements |
DC5V, using AC adapters, 220VAC/50Hz |
|
Dimensions |
210(L)×188(W)×60(H)mm |
|
Weight |
1.5kg |