Application:
AC-HTB- Series Class B Fully Automatic Horizontal Pulse Vacuum Autoclave is suitable for sterilizing unwrapped,
wrapped, solid, hollow A, hollow B, instrument with built-in pipe and implanted instrument which can withstand high temperature
and pressure in the places including oral department, ophthalmology, operation room and lab.
Technical advantage:
- PLC control, sixty-five thousand color touch screen, the system is powerful and reliable.
- Water injection automatically, accurate control, easy to operate and maintenance.
- Pulsing, heating up,sterilizing,drying process are fully automatic without artificial regulation.
- Built-in high quality vacuum pulse , vacuum pulse 1~6 times can reach -0.09 Mpa(-0.9Bar),
- to ensure effective removal of the air so as to get the optimum saturate steam.
- Inner circulation, water ring pump without external pipeline, easy to install.
- Unique pulse vacuum drying procedure is designed, and the residue moisture shall be less than 0.2%.
- Perfect fault warning system is designed, and fault messages are shown on touch screen display real-timely.
- Equipped with mini-printer is to restore sterilization cycle.
- Cycle count function.
- The beep will sound once the sterilization cycle completes and messages are shown on screen touch display at the same time.
- Safety protection device:
- Heater protection: the system will cut off its power supply once the temperature exceeds the desired value and show the alarm information.
- Anti-dry heating: anti-dry heating device will automatically cut off its power supply and show the alarm information once the water level is lower than the heating pipe.
- Safety interlock door (capacity ≤80L): Electric lock to ensure the autoclave can begin to work only if the door is closed properly. The door can’t be opened when pressure is in chamber or the power supply is not connected.
- Mechanical pressure interlock door (capacity ≥120L ): the mechanical door device is locked tightly and can’t be opened once pressure is in chamber.
- Over-temperature and over-pressure protection: the system will start up procedures to lower temperature and release pressure to protect items from being damaged when the temperature and pressure in chamber exceed the safe limit.
- Automatic release safety value: the safety value will begin to release pressure automatically when the pressure in chamber exceeds the desired value.
- Electric safety protective measure: short circuit and leakage current are designed to protect equipment and personal safety.
Main technical parameter:
- ◇ Designed pressure: 0.26MPa
- ◇ Designed temperature: 150℃
- ◇ Max. working pressure: 0.23MPa
- ◇ Sterilization temperature range: 105℃~136℃
- ◇ Temperature accurate: 0.1℃
- ◇ Temperature homogeneity: ≤±0.5℃
- ◇ Chamber material: SUS304 stainless steel
- ◇ Water requirement: distilled water or pure water
Specification:
Model |
AC60-HTB |
AC80-HTB |
AC120-HTB |
AC140-HTB |
AC160-HTB |
AC180-HTB |
Capacity |
60L |
80L |
120L |
140L |
160L |
180L |
Chamberdimensions (Φ×L) mm |
340×650 |
370×710 |
500×510 |
500×610 |
500×710 |
500×810 |
Outer dimensions (L×W×H) mm |
830×480×1355 |
870×540×1355 |
780×650×1550 |
880×650×1550 |
980×650×1550 |
1070×650×1550 |
Net weight(KG) |
175 |
185 |
252 |
275 |
290 |
310 |
Power supply(V) |
220/380 |
220/380 |
380 |
380 |
380 |
380 |
Frequency |
50HZ |
50HZ |
50HZ |
50HZ |
50HZ |
50HZ |
Power(W) |
4735 |
4735 |
6035 |
6035 |
6035 |
6035 |