AC-A Series - LED Display

Availability: In Stock
Product Code: 511
Brand: Autoclave

AC-A Series

$0

Fully Automatic Vertical Non-Pulse Vacuum Autoclave(LED Display) 

Application:

AC fully automatic vertical non-pulse vacuum autoclave (LED Display) is suitable for sterilizing surgical instruments, glassware, medium, wastes, dressings which can withstand high temperature and pressure in the places including medical health center (such as laboratory, operation room, supply room) and biomedical research institution.

Technical advantage:

  • Microcomputer control system adopted is powerful and high reliable.
  • Built-in water tank, water filling, heating up, sterilizing, drying are automatic without artificial regulation.
  • Touch screen button, procedure selected is shown on LED display real-timely,
  • simple and easy to operate.
  • Operation status, temperature and time are shown on LED display real-timely
  • Unwrapped, wrapped, dressings, rubber, user-defined, medium procedure are offered to user to select. The parameters of user-defined, medium can be regulatedaccording to requirement.
  • Various fault alarm systems are designed to display fault messages.
  • The beep will sound once the sterilization cycle completes.

    Safety protective device:

  • Anti-dry heating alarm: the system will cut off its power supply once the water level is lower than the heating pipe, and show the alarm information.
  • Safety interlock door: electric lock to ensure the autoclave can begin to work only if the door is closed properly. The door can’t be opened when pressure is in chamber or the power supply is not connected.
  • Over-temperature protection: the system will stop heating to protect items from being damaged when the temperature in chamber exceed the safe limit.
  • Over-pressure automatic release safety value: the safety value will begin to release pressure when the pressure in chamber exceeds the desired value.
  • Electric safety protective measure: short circuit and leakage current are designedto protect equipment and personal safety.

                 Main technical parameter:

  •  Designed pressure: 0.26MPa
  •  Designed temperature: 150
  •  Max. working pressure: 0.23MPa
  •  Sterilization temperature range: 105:136
  •  Temperature accurate: 0.1
  •  Temperature homogeneity: ≤±0.5
  •  Chamber material: SUS304 stainless steel
  • Water requirement: distilled water or pure water
  • Model

    Capacity

    Chamber dimensions

         (Φ×L)mm

    Outer dimensions

    (L×W×H) mm

    Net weight

    Power supply

    Frequenc

    Power

    AC-50A

    50L

    316×614

    680×508×910

    68KG

    220V

    50HZ

    2200W

    AC-80A

    80L

    375×718

    755×528×1040

    80KG

    220V

    50HZ

     3000 W

    AC-100A 100L 375×718 755×528×1040 80KG 220V 50HZ 3000 W
  •