Main Application:
By utilizing relevant parameters of apparent resistivity and induced polarization method,
the instrument is widely used in many aspects including metal and non-metal mineral
resources exploration, energy exploration, city geophysical exploration, railway and bridge
engineering exploration, etc.
Features and Functions
l Multiple functions in one Machine: not only can be used alone, but also support various functional extensions;
l High Density Measurement System: connect SG2A multichannel electrode converter (60 channels or 120 channels);
l In-hole IP Measurement: connect JD-3 in-hole IP probe
l Medium power DC IP Measurement system connect SGA9 direct current IP receiver
Main Technical Specifications
Measuring Voltage Range |
-6000mV~+6000mV |
Measuring Current Range |
0~5000mA |
Measuring Voltage Accuracy |
±1% ±1digital |
SP Compensation Range |
±1000mV |
Input impedance |
≥50MΩ |
Interference Suppression on |
50Hz |
PowerFrequency) |
|
Better than |
80dB |
Maximum Power Supply Voltage |
900V |
Maximum Power Supply Current |
5A |
Power Pulse Width |
1-59 seconds, Duty Cycle 1:1 |
Working Temperature |
-10℃ to +50℃, 95%Rh |
Volume |
305×200×202 mm |
Weight |
8 kg |