AC-HLN SERIES

Availability: In Stock
Product Code: 863
Brand: Horizontal Autoclave

AC-HLN Series

$0

Introduction:

AC- HLN  Serial automatic horizontal no vacuum pulse sterilizer is suitable for sterilizing unwrapped, wrapped, dressing package, rubber, plant in instrument, porous item (dressing), hollow instrument (high and low speed phone) which can withstand high temperature and pressure in the places including oral department, ophthalmology, operation room and lab.

Technical advantage

1.High quality plug-in microprocessor imported from America, the system is powerful and reliable.

2.Water filling, heating up, sterilizing, drying process is automatic without artificial regulation .

3. Status, temperature, pressure, time are shown on Touch screen/LCD display dynamically.

4. Perfect fault alarm system is designed, and fault messages are shown on LCD display.

5. Equipped with mini-printer is to restore the whole sterilization information.

6. Electricity is provided within 2 minutes and procedure continues to operate after cutting-off electricity.

7. Cycle count function.

8. The beep will sound once the sterilization cycle completes.

Safety protection device

Heater protection: the system will cut off its power supply once the temperature exceeds the desired value and  show the alarm information. 

Anti-dry heating: anti-dry heating device will automatically cut off its power supply and show the alarm information once the water level is lower than the heating pipe.

Safety interlock door: Electric lock to ensure the sterilizer can begin to work only if the door is closed properly. The door can’t be opened when pressure is in chamber or the power supply is not connected.

Over-temperature and over-pressure protect: the system will start up procedures to lower temperature and release pressure to protect items from being damaged when the temperature and pressure in chamber exceed the safe limit.

Automatic release safety valve: The safety valve will begin to release pressure automatically when the pressure in chamber exceeds the desired valve.

Electric safety protective measure: short circuit and leakage current are designed to protect equipment and personal safety.

Main technical parameter

Designed pressure

0.26MPa

Designed temperature

150°C

Max. working pressure

0.23MPa

Sterilization temperature range

105°C~136°C

Temperature accurate

0.1°C

Temperature homogeneity

≤±0.5°C

Chamber material

SUS304/SUS 316 stainless steel

Water requirement

distilled water or pure water

 

Model

Capacity

Chamber dimensions

(Φ×L)

Outer dimensions

(L×W×H)

Net weight

Power supply

Frequency

Power W

AC50- HLN

50L

340×550mm

730×480×1355mm

150KG

220V

50HZ

3600

AC60 -HLN

60L

340×650mm

830×480×1355mm

160KG

220V

50HZ

3600

AC80- HLN

80L

370×710mm

870×540×1355mm

180KG

380V

50HZ

5300

AC120- HLN

120L

500×510mm

780×650×1550mm

247KG

380V

50HZ

6500

AC140-HLN

140L

500×610mm

880×650×1550mm

270KG

380V

50HZ

6500

AC160- HLN

160L

500×710mm

980×650×1550mm

285KG

380V

50HZ

7100

AC180-HLN

180L

500×810mm

1070×650×1550mm

305KG

380V

50HZ

7100