Introduction:
AC- HLN Serial automatic horizontal no vacuum pulse sterilizer is suitable for sterilizing unwrapped, wrapped, dressing package, rubber, plant in instrument, porous item (dressing), hollow instrument (high and low speed phone) which can withstand high temperature and pressure in the places including oral department, ophthalmology, operation room and lab.
Technical advantage
1.High quality plug-in microprocessor imported from America, the system is powerful and reliable.
2.Water filling, heating up, sterilizing, drying process is automatic without artificial regulation .
3. Status, temperature, pressure, time are shown on Touch screen/LCD display dynamically.
4. Perfect fault alarm system is designed, and fault messages are shown on LCD display.
5. Equipped with mini-printer is to restore the whole sterilization information.
6. Electricity is provided within 2 minutes and procedure continues to operate after cutting-off electricity.
7. Cycle count function.
8. The beep will sound once the sterilization cycle completes.
Safety protection device
Heater protection: the system will cut off its power supply once the temperature exceeds the desired value and show the alarm information.
Anti-dry heating: anti-dry heating device will automatically cut off its power supply and show the alarm information once the water level is lower than the heating pipe.
Safety interlock door: Electric lock to ensure the sterilizer can begin to work only if the door is closed properly. The door can’t be opened when pressure is in chamber or the power supply is not connected.
Over-temperature and over-pressure protect: the system will start up procedures to lower temperature and release pressure to protect items from being damaged when the temperature and pressure in chamber exceed the safe limit.
Automatic release safety valve: The safety valve will begin to release pressure automatically when the pressure in chamber exceeds the desired valve.
Electric safety protective measure: short circuit and leakage current are designed to protect equipment and personal safety.
Main technical parameter
Designed pressure |
0.26MPa |
Designed temperature |
150°C |
Max. working pressure |
0.23MPa |
Sterilization temperature range |
105°C~136°C |
Temperature accurate |
0.1°C |
Temperature homogeneity |
≤±0.5°C |
Chamber material |
SUS304/SUS 316 stainless steel |
Water requirement |
distilled water or pure water |
Model |
Capacity |
Chamber dimensions (Φ×L) |
Outer dimensions (L×W×H) |
Net weight |
Power supply |
Frequency |
Power W |
AC50- HLN |
50L |
340×550mm |
730×480×1355mm |
150KG |
220V |
50HZ |
3600 |
AC60 -HLN |
60L |
340×650mm |
830×480×1355mm |
160KG |
220V |
50HZ |
3600 |
AC80- HLN |
80L |
370×710mm |
870×540×1355mm |
180KG |
380V |
50HZ |
5300 |
AC120- HLN |
120L |
500×510mm |
780×650×1550mm |
247KG |
380V |
50HZ |
6500 |
AC140-HLN |
140L |
500×610mm |
880×650×1550mm |
270KG |
380V |
50HZ |
6500 |
AC160- HLN |
160L |
500×710mm |
980×650×1550mm |
285KG |
380V |
50HZ |
7100 |
AC180-HLN |
180L |
500×810mm |
1070×650×1550mm |
305KG |
380V |
50HZ |
7100 |