Introduction
● Multi-parameter meter, equipped with pH electrode, ORP electrode and conductivity electrode, automatic identification of electrode by meter.
● Built-in microprocessor chips, intelligent functions such as automatic calibration, automatic temperature compensation, data storage, function set-up, self-diagnose information, automatic power-off and low voltage display.
●Automatic identification of 13 pH standard buffer solutions, three options of standard buffer solutions: Europe and America series, NIST series
●Able to set pH measurement modes of high purity water and pure water with ammonia.
● Automatic identification of 8 conductivity standard calibration solutions, two options of standard calibration solutions: Europe and America series
● Adopt advanced conductivity measurement technology, use conductivity electrode of constant K=1, only need one point calibration and meet the measurement precision requirement of 0.5μS/cm ~ 200 mS/cm.
● Ability to switch among conductivity, TDS, salinity and resistivity. Multinomial calculation for TDS and salinity to ensure the conversion precision of the full scale.
● Conductivity measurement mode has the function of non-linear temperature compensation for high purity water.
● Meter meets IP57 rating, equipped with calibration solution and portable case.
Specification
Category |
Product Name PH-29A |
Basic features and specifications |
PH |
Measuring range |
(-2.00 ~ 19.99)pH |
|
Resolution |
0.1/0.01 pH |
|
Accuracy |
Meter:±0.01pH; Overall: ±0.02pH |
|
Input current |
≤2×10-12 A |
|
Input impendance |
≥1×1012 Ω |
|
Stability |
±0.01 pH/3h |
|
Temp. compensation range |
(0 ~ 100)℃(automatic) |
ORP |
Measuring range (mV/ORP/EH) |
-1999mV ~ 0 ~ 1999mV |
|
Resolution |
1mV |
|
Accuracy |
Meter:±0.1% FS, Overall: ±15mV |
Conductivity |
Measuring range |
Conductivity:(0.00~19.99)μS/cm (20.0~199.9)μS/cm (200~1999)μS/cm (2.00~19.99)mS/cm (20.0~199.9)mS/cm TDS: (0 ~ 100)g/L Salinity: (0 ~ 100)ppt Resistivity:(0 ~ 100)MΩ·cm |
|
Resolution |
0.01/0.1/1μS/cm 0.01/0.1 mS/cm |
|
Accuracy |
Meter:±1.0% FS, Overall:±1.5% FS |
|
Temp. compensation range |
(0 ~ 50)℃(manual) |
|
Electrode constant |
0.1 / 1 / 10 cm-1 |
|
Benchmark temperature |
25℃、20℃ and 18℃ |
Other Technical Parameters |
Data storage |
200 groups |
|
Storage content |
Series number, measuring value measuring unit and temperature, |
|
Power |
Two AA batteries (1.5V x2) |
|
Size and weight |
meter:(65×120×31)mm/180g; Suitcase: (360×270×76)mm/1.6Kg |
Working Condition |
Environment temperature |
5 ~ 35 ℃(0.01grade) |
|
Environmental humidity |
≤85% |
|
IP rating |
IP57 Dustproof and waterproof |
Standard Kit Includes
1. PH-29A pH/ORP/Conductivity meter |
1set |
2. 201T-S plastic pH/ATC three-in-one combined electrode |
1pcs |
3. 301Pt-S plastic ORP combined electrode |
1pcs |
4. 2301-S plastic conductivity electrode |
1pc |
5. pH standard buffer solution(pH4.00, pH7.00 and pH10.01/50mL) |
1btl/each |
6. 1413 μS/cm conductivity standard solution (50mL) |
1bottle |
7. Screw driver |
1pcs |
8. Spare AA batteries |
2pcs |
9. Operation manual |
1pcs |
10. Carrying case |
1unit |